Home ] Up ] GSE Parts Department ] Feedback ] HOBART GROUND POWER ] Hobart Ground Power 400Hz & DC Data Sheets ] 400Hz POWER & DISTRIBUTION ] 400 Hz & DC LOAD BANKS ] HOBART PARTS QUOTE ] COLEMAN ENGINEERING ] HOBART GPU QUOTE ] Trilectron Ground Equipment ] Hangar 400Hz & DC Power Systems ] Aircraft Air Conditioners ] Hobart GPU Manuals ] AGE Corp Military Products ● Freeport ● NY ]


Home
Up
GSE Parts Department
Feedback
HOBART GROUND POWER
Hobart Ground Power 400Hz & DC Data Sheets
400Hz POWER & DISTRIBUTION
400 Hz & DC LOAD BANKS
HOBART PARTS QUOTE
COLEMAN ENGINEERING
HOBART GPU QUOTE
Trilectron Ground Equipment
Hangar 400Hz & DC Power Systems
Aircraft Air Conditioners
Hobart GPU Manuals
AGE Corp Military Products ● Freeport ● NY
 

HOBART DATA SHEETS

GET A QUOTE

Terms & Conditions of sale

Performance Specifications

Engine                                                                                                                                                     

  • Deutz BF6MI013E diesel operating at 2400 RPM provides 197 horsepower
  • Turbocharged 4-stroke, inline 6 cylinder
  • Full application approval by Deutz Corp.
  • 12VDC battery system
  • Low oil pressure shutdown
  • High coolant temperature shutdown
  • Intake air restriction indication
  • Stop lever governing for precise control and longer life
  • Electronic governor
  • Fuel cooler system

Environmental

  • Operation temperature:
       -25ºF to +125ºF
       -31ºC to +52ºC
  • Relative humidity 0 - 100% non condensing
  • No altitude derating required up to 5,000 feet, when running in normal operating range

Performance

  • Rating: 120kVA, 96kW, 3 phase, 4 wire, 115/200 volt Wye, continuous
  • Dual output (protected)
  • Meets or exceeds MIL-STD-704E Electrical Power Quality Requirements

Overload

  • 125% rated load for 5 minutes, 150% for 10 seconds
  • Output: 324 amps, 5 minutes

Voltage

  • Transient voltage recovery time: to within ±1% in 100 milliseconds (no load to rated load)
  • Within ±20% deviation upon application/removal of 100% load rating
  • Modulation: does not exceed 0.5% of steady state voltage
  • Phase voltage displacement with balanced load: 120º ±1.5º
  • Phase voltage balance with unbalanced load: does not exceed 4% with 1/3 rated current on any single phase with other two phases disconnected
  • Crest factor: 1.414 ±0.07
  • Individual Harmonic Distortion: < 2% of the fundamental (RMS) voltage
  • Total Harmonic Distortion: < 3% of the fundamental (RMS) voltage

Regulation

  • Voltage regulation: ±1% no load to full load
  • Voltage adjust: ±15 volts
  • Three phase average sensing, built-in line drop compensation, up to 5%

Frequency

  • Regulation: ±2Hz steady state
  • Transient recovery: to within ±0.5% (2Hz) in < 2 seconds
  • Modulation: <0.25% (1Hz)

Protection

  • Meets MILSTD-704E
  • Overvoltage: instantaneous disconnection of load at 180 volts L-N, with inverse time delay down to 126 volts in 2 seconds
  • Undervoltage: disconnects output below 100 volts L-N in 7 seconds
  • Overfrequency: disconnects output above 420Hz in 5 seconds
  • Underfrequency: disconnects output below 380Hz in 7 seconds

Finish

  • Anti-corrosive powdered epoxy primer, electro statically applied to metal parts and sheet metal with Dupont Gloss white topcoat over black frame
  • Resists glycol, skydrol and like corrosives

Displays/Instrumentation

Engine Operation

  • Meters: coolant temperature, ammeter, hour meter, oil pressure, fuel level
  • Indicator lights: engine circuit on, air cleaner restriction, high coolant temperature, low oil pressure, engine stop delay active, low fuel
  • Switches: Engine start. engine stop, panel lights
  • Delayed shutdown for turbocharger protection

Generator Output

  • Meters: frequency, ammeter, voltmeter
  • Indicator Lights: contactor(s) on, overfrequency, underfrequency, overload, overvoltage, undervoltage
  • Switches: meter select, contactor(s), test/reset

Trailer

  • Tire size: 20.5 x 8.00 - 10
  • Ground clearance: 9" (.23m)
  • Brakes: Tow bar activated, drum type

Options

  • Noise reduction kit
  • Glow plug starting aid
  • Block heater kit (115V/6OHz or 240V/5OHz)
  • Transformer-Rectifier pack for 28.5VDC
  • Automatic towbar height stop
  • Unit operating light
  • Pintle or pin hitch
  • Spot light
  • Alternative mounting configuration: stationary/fixed or truck mounted
  • Special paint scheme
  • Hand activated brakes
  • Battery blanket
  • Indicator beacons

Gross Weight

  • 6400 lbs. (2903 kg)

Specifications subject to change without notice.


 

 

(516) 546-0003            (800) 758-0044

GSE Parts Department ] Feedback ] HOBART GROUND POWER ] Hobart Ground Power 400Hz & DC Data Sheets ] 400Hz POWER & DISTRIBUTION ] 400 Hz & DC LOAD BANKS ] HOBART PARTS QUOTE ] COLEMAN ENGINEERING ] HOBART GPU QUOTE ] Trilectron Ground Equipment ] Hangar 400Hz & DC Power Systems ] Aircraft Air Conditioners ] Hobart GPU Manuals ] AGE Corp Military Products ● Freeport ● NY ]