HOBART DATA SHEETS
GET A QUOTE



Terms & Conditions of sale
| |
|
Performance Specifications
Engine
- Deutz BF6MI013E diesel operating at 2400 RPM provides 197 horsepower
- Turbocharged 4-stroke, inline 6 cylinder
- Full application approval by Deutz Corp.
- 12VDC battery system
- Low oil pressure shutdown
- High coolant temperature shutdown
- Intake air restriction indication
- Stop lever governing for precise control and longer life
- Electronic governor
- Fuel cooler system
Environmental
- Operation temperature:
-25ºF to +125ºF
-31ºC to +52ºC
- Relative humidity 0 - 100% non condensing
- No altitude derating required up to 5,000 feet, when running in
normal operating range
Performance
- Rating: 120kVA, 96kW, 3 phase, 4 wire, 115/200 volt Wye, continuous
- Dual output (protected)
- Meets or exceeds MIL-STD-704E Electrical Power Quality Requirements
Overload
- 125% rated load for 5 minutes, 150% for 10 seconds
- Output: 324 amps, 5 minutes
Voltage
- Transient voltage recovery time: to within ±1% in 100 milliseconds
(no load to rated load)
- Within ±20% deviation upon application/removal of 100% load rating
- Modulation: does not exceed 0.5% of steady state voltage
- Phase voltage displacement with balanced load: 120º ±1.5º
- Phase voltage balance with unbalanced load: does not exceed 4% with
1/3 rated current on any single phase with other two phases
disconnected
- Crest factor: 1.414 ±0.07
- Individual Harmonic Distortion: < 2% of the fundamental (RMS)
voltage
- Total Harmonic Distortion: < 3% of the fundamental (RMS) voltage
Regulation
- Voltage regulation: ±1% no load to full load
- Voltage adjust: ±15 volts
- Three phase average sensing, built-in line drop compensation, up to
5%
Frequency
- Regulation: ±2Hz steady state
- Transient recovery: to within ±0.5% (2Hz) in < 2 seconds
- Modulation: <0.25% (1Hz)
Protection
- Meets MILSTD-704E
- Overvoltage: instantaneous disconnection of load at 180 volts L-N,
with inverse time delay down to 126 volts in 2 seconds
- Undervoltage: disconnects output below 100 volts L-N in 7 seconds
- Overfrequency: disconnects output above 420Hz in 5 seconds
- Underfrequency: disconnects output below 380Hz in 7 seconds
Finish
- Anti-corrosive powdered epoxy primer, electro statically applied to
metal parts and sheet metal with Dupont Gloss white topcoat over black
frame
- Resists glycol, skydrol and like corrosives
Displays/Instrumentation
Engine Operation
- Meters: coolant temperature, ammeter, hour meter, oil pressure, fuel
level
- Indicator lights: engine circuit on, air cleaner restriction, high
coolant temperature, low oil pressure, engine stop delay active, low
fuel
- Switches: Engine start. engine stop, panel lights
- Delayed shutdown for turbocharger protection
Generator Output
- Meters: frequency, ammeter, voltmeter
- Indicator Lights: contactor(s) on, overfrequency, underfrequency,
overload, overvoltage, undervoltage
- Switches: meter select, contactor(s), test/reset
Trailer
- Tire size: 20.5 x 8.00 - 10
- Ground clearance: 9" (.23m)
- Brakes: Tow bar activated, drum type
Options
- Noise reduction kit
- Glow plug starting aid
- Block heater kit (115V/6OHz or 240V/5OHz)
- Transformer-Rectifier pack for 28.5VDC
- Automatic towbar height stop
- Unit operating light
- Pintle or pin hitch
- Spot light
- Alternative mounting configuration: stationary/fixed or truck
mounted
- Special paint scheme
- Hand activated brakes
- Battery blanket
- Indicator beacons
Gross Weight
Specifications subject to change without notice.
|
|
| |
|